{"title":"Services","description":"","products":[{"product_id":"erstinbetriebnahme-stromerzeuger-bis-12-5kva","title":"Initial Commissioning for Generators up to 12.5 kVA","description":"\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eInitial Commissioning of Your Generator\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eYou receive this product ready to run\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eA generator is an investment that has to work reliably when it matters – and that is exactly what our initial commissioning ensures. Before your new generator is delivered to you, it goes through a complete inspection and preparation process with us, so you can use it straight out of the box without having to worry about oil, the battery or the first start.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eGenerators are usually shipped from the factory without engine oil and with an uncharged starter battery. This is where most early failures occur in practice: the wrong oil or too little of it, an insufficiently charged battery, overlooked transport damage or an improper first start under full load. Our initial commissioning eliminates these risks, and you receive a documented, tested unit that is ready for use.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eOur experienced technicians start with a thorough visual inspection of the entire generator, checking it for transport damage, loose connections and the correct fit of all attached parts. All operating fluids are then filled to the quality specified by the manufacturer – including high-quality branded engine oil of the right viscosity and, depending on the model, other operating fluids. On electric-start models, we check the starter battery's open-circuit voltage and starting capability and then fully recharge it, so your generator arrives ready to start.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eAs part of the filter check, we inspect the air filter, fuel filter and – where fitted – the oil filter element for correct fit and perfect condition. The subsequent electrical test includes measuring voltage and frequency at all sockets, a phase rotation test on three-phase generators and a function check of all safety devices such as low-oil shutdown, overload protection and RCD.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThe final step is a test run under real conditions. After an idle test run, the generator is loaded with two different types of load: a resistive load (e.g. a heating load) and an inductive load (e.g. a motor load). This allows the behaviour of the alternator, AVR or inverter to be reliably assessed under realistic load – weaknesses that a simple idle test would not reveal become visible here.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eYou receive your generator inspected, filled, with a charged battery and load-tested – ready for its first use, whether in everyday commercial operation, on the construction site, at an event or as a backup generator at home.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eThis product includes the following services:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eVisual inspection of the generator for transport damage and correct fit of all attached parts\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFilling of all operating fluids incl. branded engine oil of the right viscosity\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eBattery test (open-circuit voltage, starting capability) and full recharge on electric-start models\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFilter check: air filter, fuel filter and oil filter element (depending on model)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eElectrical test: voltage, frequency, phase rotation, function check of all safety devices\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eIdle test run\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eLoad test with two different types of load (resistive and inductive)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kipor.org","offers":[{"title":"Default Title","offer_id":53793807794518,"sku":null,"price":399.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0901\/3149\/7302\/files\/KIPORServicebis12_5kva.png?v=1779104926"},{"product_id":"erstinbetriebnahme-stromerzeuger-bis-20kva","title":"Initial Commissioning for Generators up to 20 kVA","description":"\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eInitial Commissioning for Generators up to 20 kVA\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eGenerators with outputs of up to 20 kVA are usually the backbone of commercial power supply – whether as a backup generator for your business, the main power source on a construction site, at events, in hire fleets, for emergency services or in agriculture. That is exactly why a generator of this size should be commissioned under professional conditions right from the start. With our initial commissioning service, you receive your generator inspected, filled and tested under real load – ready for its first use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eWith larger generators in particular, a professional initial inspection is much more than just \"add oil and switch on\". Diesel and three-phase generators have more components that need to work together: glow plug system, fuel system, cooling circuit (on water-cooled models), starter battery, control electronics and – depending on the equipment – ATS interface, AMF control or soundproof canopy. Faults in these areas often do not show up on the first start, but only under load – exactly where things get expensive.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eOur experienced technicians start with a thorough visual inspection of the entire generator, including checks for transport damage, loose screw connections and the correct fit of all attached parts, the soundproof canopy and the controls. All operating fluids are then filled to the quality specified by the manufacturer – branded engine oil of the right viscosity and, depending on the model, coolant and fuel for the test run. On electric-start models (standard in this power class), we check the starter battery's open-circuit voltage, load capacity and starting capability and then fully recharge it.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eAs part of the filter check, we inspect the air filter, fuel filter, water separator and – where fitted – the oil filter element for correct fit and perfect condition. The electrical test includes measuring voltage and frequency at all sockets and outlets, a phase rotation test on three-phase generators, a function test of the control panel and a check of all safety devices such as low-oil shutdown, overload and overtemperature protection, RCD and, where fitted, the emergency stop. On request and where technically available, we also check that the ATS interface is working properly.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThe final step is a test run under real conditions. After an idle test run, the generator is put under full load with two different types of load – a resistive load (e.g. a heating load) and an inductive load (e.g. a motor load). Only under this real load does it become clear how the alternator, AVR or control system actually behave. This reveals problems that would remain hidden in a pure idle test – before the generator goes into productive use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eYou receive your generator inspected, filled, with a charged battery and tested under full load – ready for immediate use in demanding everyday commercial operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eThis product includes the following services:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eVisual inspection of the generator incl. soundproof canopy, attached parts and controls\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFilling of all operating fluids incl. branded engine oil and coolant where required\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eBattery test (open-circuit voltage, load capacity, starting capability) and full recharge\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFilter check: air filter, fuel filter, water separator, oil filter element (depending on model)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eElectrical test: voltage, frequency, phase rotation, control panel and safety devices\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFunction test of the ATS interface (if fitted)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eIdle test run\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFull-load test with two different types of load (resistive and inductive)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Kipor.org","offers":[{"title":"Default Title","offer_id":53793907933526,"sku":null,"price":449.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0901\/3149\/7302\/files\/KIPORservicebis20kVA.png?v=1779104959"}],"url":"https:\/\/www.kipor.org\/en\/collections\/services.oembed","provider":"Kipor.org","version":"1.0","type":"link"}